- > Could anybody PLEASE tell me how I can send a string (for example
- > 'ATH1') to the modem? I want to create a program that dials a number
- > and then automaticly enters a few other numbers....
- > so, for example:
-
- Without giving you a complete com-unit here's something that will do the
- trick.
- }
- uses crt;
- const
- RBR = $00; { Receive Buffer offset }
- THR = $00; { Transmitter Holding offset }
- IER = $01; { Interrupt Enable offset }
- IIR = $02; { Interrupt Identification offset }
- LCR = $03; { Line Control offset }
- MCR = $04; { Modem Control offset }
- LSR = $05; { Line Status offset }
- MSR = $06; { Modem Status offset }
- DLL = $00; { Divisor Latch Low byte }
- DLH = $01; { Divisor Latch Hi byte }
- CMD8259 = $20; { Interrupt Controller Command offset }
- IMR8259 = $21; { Interrupt Controller Mask offset }
-
- Var Combase: Word; { Hardware Com-port Base Adress }
-
- Function Carrier : boolean;
- { To detect carrier on remote port, requires combase to be set to the }
- { correct com base address }
- begin
- carrier := port[Combase + MSR] and $80 = $80;
- end;
-
- Procedure RaiseDTR;
- { To raise the DTR signal bit 0 of the mcr must be changed to on }
- begin
- port[combase + msr] := port[combase + mcr] or $1;
- end;
-
- Procedure LowerDTR;
- { To lower the DTR signal, causing carrier loss, bit 0 must be turned }
- { off }
- begin
- port[combase + msr] := port[combase + mcr] and not $1;
- end;
-
- Procedure Writeport(st : string);
- { This procedure takes a string from the parameters and sends each }
- { character making sure that the com base address is not equal to 0 (not }
- { Installed) }
- Var
- Count,LoopLimit: word; { Time out counter }
- loop: byte;
- Begin
- LoopLimit := 2000;
- for loop := 1 to length(st) do begin
- Count := 0;
- Repeat
- inc(Count);
- Until ((port[Combase + LSR] and $20) <> 0) or (Count > LoopLimit);
- If Count < LoopLimit then port[Combase+THR] := byte(st[loop]);
- End;
- End;
-
- Procedure Hangup;
- { To drop carrier to hangup the phone -- Simple eh? }
- Begin
- lowerdtr; { Drop DTR }
- delay(500);
- { If the modem can't handle DTR drops go back to grade school and use }
- { Hayes compatiable hangups }
- if carrier then begin
- writeport('+++');
- delay(1000);
- writeport('ATH0'#13);
- End;
- End;
-
- Procedure Initport(Cb : word; Baudrate : word; Bits : Byte; Parity : Char; Stop
- : byte);Var
- tempstop,temppar: byte;
- tempbaud: word;
- Begin
- Combase := Cb; { Set Comport baseadress }
-
- if stop = 1 then tempstop := $0 { Decode the stopbits }
- else tempstop := $04;
- case upcase(Parity) of { Decode parity }
- 'S': tempPar := $38;
- 'O': tempPar := $08;
- 'M': tempPar := $28;
- 'E': tempPar := $18;
- 'N': tempPar := $00;
- end;
- case baudrate of { Decode baud rate }
- 110 : tempbaud := $417;
- 150 : tempbaud := $300;
- 300 : tempbaud := $180;
- 600 : tempbaud := $C0;
- 1200 : tempbaud := $60;
- 2400 : tempbaud := $30;
- 4800 : tempbaud := $18;
- 9600 : tempbaud := $0C;
- 19200 : tempbaud := $06;
- { 38400 : tempbaud := $03;
- 57600 : tempbaud := $02;
- 115200 : tempbaud := $01; {-- Outside of ordinal range}
- End;
-
- port[Combase+LCR] := $80; { Adress Divisor Latch }
- port[Combase+DLH] := Hi(tempbaud); { Set Baud rate }
- port[Combase+DLL] := Lo(tempbaud);
- port[Combase+LCR] := $00 or temppar { Setup Parity }
- or (Bits - 5) { Setup databits }
- or tempstop; { Setup stopbits }
- port[Combase+MCR] := $0B; { Set RTS, DTR }
- End;
-
- begin
- initport($3F8,19200,8,'N',1);
- writeport('ATD'#13);
- end.
-
- {
- Please note that this program is well.. unable to recieve characters, if
- you're to poll the CTS/RTS every so often you could check it easily and
- you'd have a non-interrupt driven comm routine, probably end up loosing
- characters left & right, but it would work for what you're trying to do
- and save some coding. Anyhow this should get you started.
- }